A 199,000 BTU tankless unit needs about 193 cubic feet per hour of natural gas. Over a 40 foot run at a half inch water column drop, the NFPA 54 table gives 3/4 inch pipe a capacity of 170 cubic feet per hour, so that run needs 1 inch pipe.
Result
Gas piping, flue and vent work is for a licensed plumber or gas fitter. An undersized gas line starves a burner, and a starved burner produces carbon monoxide. This figure is for planning a conversation, not for doing the work.
The formula
Required CFH = BTU/h / 1,030 BTU per cubic foot. Then read the smallest pipe size whose NFPA 54 capacity at that run length meets or exceeds it.
The table is Schedule 40 metallic pipe, natural gas at 0.60 specific gravity, less than 2 psi inlet, half inch water column pressure drop. Code sizing uses the longest run from the meter to any outlet, and every elbow and tee adds equivalent length that this does not account for. This is a planning figure. The person who signs the permit does the real sizing.
The figures above are computed with these exact inputs: Appliance input 199000 BTU/h, Longest run from the meter 40 ft, Fuel naturalGas.
Some of these are published test procedures or code tables and some are planning conventions. They are not the same kind of number, so each one is labeled.
| Assumption | Kind | Where it comes from |
|---|---|---|
| NFPA 54 and IFGC pipe capacity table | Published standard | NFPA 54 and IFGC pipe capacity table, Schedule 40 metallic pipe, natural gas at 0.60 specific gravity, less than 2 psi inlet, 0.5 in water column drop |
| Btu Per Cuft Ng: 1030 | Published standard | Typical published higher heating value of pipeline natural gas. Your utility publishes its actual figure on the bill |
Every card below is in the page source. The calculator re-ranks them against your numbers and marks anything that falls short of what you just calculated.
Braided stainless with a swivel nut, which lets the tank be set down and then connected rather than threaded into place.
Best for: A standard tank replacement
Check price on Amazon
Corrugated stainless rather than braided, which bends tighter and suits a tank pushed close to a wall.
Best for: A tight tank closet
Check price on Amazon
The 24 inch length, for when the new tank is shorter than the old one and the pipe stub no longer lines up.
Best for: Replacing a tall tank with a short one
Check price on Amazon
A straightforward 24 inch female iron pipe connector, which is the fitting almost every residential tank uses.
Best for: A standard threaded tank
Check price on Amazon
A ball valve built into the connector, which puts a shutoff on the cold inlet without adding a separate fitting and a separate joint.
Best for: A tank with no cold inlet shutoff
Check price on Amazon
Full port 3/4 inch, which matters on a tankless unit because a restricted connector throttles the input the whole sizing calculation assumed.
Best for: A gas tankless unit
Check price on AmazonResearched guidance, not professional advice. These results are planning figures from published test procedures, code tables and manufacturer specifications, and they do not replace a sizing done by the person who will sign the permit. A water heater is a pressure vessel: never cap, plug or remove the temperature and pressure relief valve, and replace one that will not open when the test lever is lifted. Gas line, flue and vent work belongs to a licensed plumber or gas fitter, because improper venting produces carbon monoxide. Water at 140 F scalds a child in seconds. Turn off the breaker before touching an element, and never energise an element that is not submerged.